You can configure additional options.

 

 

1)Edit all fields of the Option tab.

bs240_eleve_add_option_en_01

 

No.

Item

Description

1

Relay Control

You can configure options concerning the activating of the relay of the floor.

 

Open Time: Set the duration for which the floor button will remain activate after a user authentication is completed. When the authentication is successful, the relay will be activated for the set time. When this time elapses, the relay no longer sends the signal to the relay of the floor.

2

Dual Authentication

You can configure the floor button to activate only when authenticating credentials of two persons (an ordinary user and an administrator).

 

Device: Select a device to use dual authentication. If No device is selected, the dual authentication mode is disabled.

 

0185-clipboard Note

If you want to use the Dual Authentication feature on the device previously set as either the Entry Device or the Exit Device in Occupancy Limit Zone, click Zone > Occupancy Limit and set the device as either the Entry Device or the Exit device again. For more information, refer to Occupancy Limit Zone.

 

Schedule: Set a schedule to use dual authentication. If no desired schedule is available, click + Add Schedule to create it. For more information on configuring schedules, see Schedules.
Approval Type: You can configure the administrator authentication order. Setting to None will require two users to authenticate regardless to the access group. Setting to Last will require an authentication by a user belonging to an access group that has been set after a normal user authentication.
Authentication Group: You can configure a group to which the administrator belongs.
Authentication Timeout: Set a timeout period for authenticating the second credential after the first credential has been authenticated. If the second credential is not authenticated within the timeout period after the first credential has been authenticated, the door will not open.

3

Tamper

You can set a port to output the tamper signal.

 

2)Click Apply to save the settings.

 