You can configure additional options.

 

 

1)Edit all fields of the Option tab.

Door_option_en_1

 

No.

Item

Description

1

Open

You can configure options concerning the opening of the door.

 

Open Time: Set the duration for which the door will remain open after a user authentication is completed. When the authentication is successful, the relay will be activated for the set time. When this time elapses, the relay no longer sends the signal to the door.

 

0185-clipboard Note

Open Time may vary depending on the type of door lock used.

 

Lock when door is closed: When the door sensor detects that the door is closed, the door is locked.  This option is not available if Use Automatic Door is set to ON.
Use Automatic Door: When using an automatic door as an entrance door, a relay can operate regardless of the status of a door sensor. This option is not available if Lock when door is closed is set to ON.

2

Dual Authentication

You can configure the door to open only when authenticating credentials of two persons (an ordinary user and an administrator).

 

Device: Select a device to use dual authentication. If No device is selected, the dual authentication mode is disabled.

 

0185-clipboard Note

If you want to use the Dual Authentication feature on the device previously set as either the Entry Device or the Exit Device in Occupancy Limit Zone, click Zone > Occupancy Limit and set the device as either the Entry Device or the Exit device again. For more information, refer to Occupancy Limit Zone.

 

Schedule: Set a schedule to use dual authentication. If no desired schedule is available, click + Add Schedule to create it. For more information on configuring schedules, refer to Schedules.
Approval Type: You can configure the administrator authentication order. Setting to None will require two users to authenticate regardless to the access group. Setting to Last will require an authentication by a user belonging to an access group that has been set after a normal user authentication.
Authentication Group: You can configure a group to which the administrator belongs.
Authentication Timeout: Set a timeout period for authenticating the second credential after the first credential has been authenticated. If the second credential is not authenticated within the timeout period after the first credential has been authenticated, the door will not open.

3

Anti-Tailgating

You can configure the door to detect the tailgating.

 

Sensor: You can select the sensor to detect tailgating.

 

2)Click Apply to save the settings.

 