Interlock zone monitors the status of two or more doors by door sensor and relay state to control that one door cannot be opened or close if other doors are open or unlocked. You can also disable access if a user stays within the zone.

 

0185-clipboard Note

An interlock zone can be configured with up to 4 doors.
An interlock zone can only set the doors with the devices connected to the CoreStation.
A device set as an interlock zone cannot be set to another zone.
A door set as an interlock zone cannot be set to another zone other than the fire alarm zone.

 

 

1)Click ZONE and click ADD ZONE.
2)Click Interlock and click Apply.
3)Edit the necessary items.

zone_interlock_en_1

 

No.

Item

Description

1

Information

Modify the information of the interlock zone.

 

Name: Enter an interlock zone name.
Type: View the zone type.

2

Configuration

You can change the general settings of an interlock zone.

 

Mode: You can check the application range of the zone. Only Local mode is supported for interlock zone, and the zone can be set only with devices connected to the CoreStation and RS-485.
Active/Inactive: You can disable the interlock zone. Select Active to enable it.
Door: Select the doors to include in the interlock zone. You must select at least two doors that are the door sensor is connected.

3

Option

If a user stays in the zone, this option can prevent others from entering the zone.

 

0185-clipboard Note

It is activated only when Door is set from Configuration.

4

Alarm

Set the alarm action to carry out when a specific event occurs at the interlock zone.

 

0185-clipboard Note

It is activated only when Door is set from Configuration.

 

4)Click Apply to save the settings.

 